TM 1-1520-238-MTF 2-42 PROCEDURE TROUBLESHOOTING REFERENCE AFTER STARTING APU (CONT) g.   ACM switch – ACM. Verify no excessive change in image quality. h.   ACQ SEL switch – OFF. Verify proper turret response to head movement. No excessive blooming of picture. i.   Image registration – Check. (1)   Align crewmembers LOS forward to the 12 o’clock position ±5°. (2)   Select a reference object approximately 90 feet in front of helicopter. NOTE The allowable registration error is 1 foot at 90  feet.    The  center  open  position  of  the LOS reticle is equivalent to 1 foot at 90 feet. (3)   Check registration (alignment differential) between the thermal image and reference object in azimuth. j.   ACM switch – As desired. k.   ACQ SEL switch – As required. 24.   Sensor changeover – Check as follows: a.   Pilots changeover check:

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing