TM 1-1520-238-MTF 2-36 PROCEDURE TROUBLESHOOTING REFERENCE AFTER STARTING APU (CONT) (f)   IAT switch – Deactivated. (5)   Range focus adjustment – Check as follows: (a)   Select a target at least 500 meters distant. (b)   FOV switch – N. (c)   RNG FOC switch – Actuate through full range. Adjust as required to optimize image. (6)   NT filter select switch – Actuate. Verify proper function of night filter. (7)   SLAVE switch – Actuate to return turret to fixed forward stow. i.   Laser spot tracker – Check as follows: (1)   LTAUTO. (2)   SLAVE switch – Actuate. Verify TADS turret enters a four bar search pattern. (3)   LTOFF. Verify TADS turret stops. (4)   SLAVE switch – Actuate.