i.   Laser spot tracker

TM 1-1520-238-MTF 2-35 PROCEDURE TROUBLESHOOTING REFERENCE AFTER STARTING APU (CONT) (3)   ACM switch – Engage. Note any adverse effects on image quality; reoptimize imagery as required. (4)   IAT/IAT OFS check – Slew turret to a target of relatively high contrast differential: (a)   IAT polarity switch – Select appropriate polarity for image lockon. (b)   IAT MAN switch – Engage. Verify proper lockon of selected image. (c)   IAT OFS switch – Actuate. Verify turret responds to thumbforce controller commands and allows movement about 20 percent of the available field of view. (d)   IAT OFS switch – Reactuate. Observe TADS crosshairs move smoothly towards IAT target, then jump suddenly onto the selected target. (e)   FLIR PLRT select switch – Verify tracking capability in both WHT and BLK positions.