AFTER STARTING APU (CONT)
Up
TM-1-1520-238-MTF Maintenance Test Flight Manual Helicopter Attack AH-64A Apache
Next
d.   Autodrift null check

TM 1-1520-238-MTF 2-29 PROCEDURE TROUBLESHOOTING REFERENCE AFTER STARTING APU (CONT) (7)   INTR LT INST control – On. Check reticle brightness corresponds to control position through full range. Then set as desired. (8)   Align HMD reticle with BRU. (9)   HMD BRSIT switch – Actuate then release. (10)   BRSIT IHADSS switch – OFF. (11)   INTR LT INST control – As desired. (12)   SIGHT SEL switch – As required. *22.   TADS – Complete operational checks and boresight as required. a.   Grayscale adjust check: (1)   GS switch – Actuate, Verify symbology replaced by grayscale on HOD. (2)   ORT BRT and CONT controls – Actuate through full range and adjust for optimum scaling. (3)   HDD switch – Actuate. Repeat steps (1) and (2) above. Return to HOD operations.