(2)   ADF operation

TM 1-1520-238-MTF 2-21 PROCEDURE TROUBLESHOOTING REFERENCE AFTER STARTING APU (CONT) (c)   LOOP L-R control – Adjust to obtain a maximum deflection on TUNE meter. This should be 90° from the station. (d)   AUDIO control – Adjust for a reading that is below 3 divisions on the TUNE meter. (e)   Repeat steps (c) and (d) until a sharp peak in reading is obtained. NOTE If TUNE meter changes, impedance match- ing amplifier requires adjustment. (f)   Mode selector – ANT. Note TUNE meter indication. (g)   ADF – Set as required. *b.   AN/ARN-149 ADF Radio – Test as follows: (1)   ANT mode operation. (a)   Mode selector – ANT. (b)   HSI No. 2 bearing pointer is 90° from aircraft heading.