AFTER STARTING APU (CONT)

TM 1-1520-238-MTF Change 3 2-20 PROCEDURE TROUBLESHOOTING REFERENCE AFTER STARTING APU (CONT) (d)   Note HSI and RMI bearing indications are within ± 5° of station bearing (if known). NOTE Direction of rotation during TEST and with switch  released  is  indicative  of  signal strength and shortest distance to rotate, re- spectively. (e)   CW-VOICE-TEST switch – TEST. Note HSI and RMI bearing indicators rotate 180° ± 5°. (f)   CW-VOICE-TEST switch – CW or VOICE as appropriate. Note bearing pointers return to previously noted bearing ± 5°. (3)   LOOP mode operation: (a)   Mode selector – LOOP. NOTE Audio  tone  should  increase  and  decrease approximately  each  90°  from  originally noted bearing. (b)   LOOP L-R control – Adjust to obtain null. Adjust to obtain the opposite null approximately 180° from original bearing.