TM 1-1520-238-23 12-69 12.21. APU FIRE PANEL LIGHT INDICATING PANEL RECEPTACLE REPLACEMENT (AVIM) 12.21.1.  Description This task covers: Removal. Cleaning. Inspection. Installation. 12.21.2.   Initial Setup Tools: Electrical tool kit (item 378, App H) Personnel Required: 68X Armament/Electrical System Repairer 68X3F Armament/Electrical System Repairer/ Technical Inspector Equipment Conditions: Ref Condition 12.18 APU  fire  panel  light  indicating  panel  re- moved 12.21.3.   Removal a.   Detach wire (1) from terminal (2). (1)   Remove screw (3), lockwasher (4), and termi- nal lug (5). (2)   Remove wire (1). GO TO NEXT PAGE M04-2937-1 M04-2937-2 1 5 3 4 2