TM 1-1520-238-23 12-60 12.19. APU FIRE PANEL SWITCH REPLACEMENT (AVIM) - continued 12.19.3.  Removal WARNING Soldering gun can cause severe burns to personnel and start fires. Observe all  safety  precautions  when  using soldering  gun.  If  injury  occurs,  seek medical aid. a.   Desolder wires (1) from fire pull switch (2). (1)   Identify and desolder wires (1) from terminals (3). Use soldering gun (TM 55-1500-323-24). b.   Identify and depin two wires (4) and (5) from receptacle (A138)J1 (6) (TM 55-1500-323-24). c.   Remove switch (2) from support panel (7). (1)   Remove two screws (8). (2)   Remove and discard switch (2). GO TO NEXT PAGE M04-2935-3 1 3 1 2 VIEW ROTATED M04-2935-16 6 4 5 7 2 8 VIEW ROTATED M04-2935-4