TM 1-1520-238-23 1-30 1.15. FUEL SERVICING - CLOSED CIRCUIT REFUELING (CCR) METHOD – continued q.   Disconnect battery (1). (1)   Detach  connector  P87  (2)  from  receptacle (BT1)J3 (3). r.   Remove static ground lines (FM 10-68). s.   Secure access doors R160 and R295; install cover R180 (para 2.2). END OF TASK M04-1593-10 1 1 3 2