Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: Section II. EMERGENCY EQUIPMENT
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive

Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Figure   2-14. Crewmember Seat (Both Crew Stations)
Up
TM-1-1520-238-10 Helicopter Attack AH-64A Apache Manual
Next
Figure   2-15. Fire Detection and Extinguishing Controls

TM 1-1520-238-10 2-19 Section  II. EMERGENCY EQUIPMENT 2.14  GENERAL. Emergency  equipment  on  the  helicopter  consists  of  fire extinguishing equipment and two first aid kits (fig 9-1). WARNING Exposure to high concentrations of fire extinguishing  agent  or  decomposition products  should  be  avoided.  The  gas should  not  be  allowed  to  contact  the skin; it could cause frostbite or low tem- perature burns. If agent comes in contact with skin, seek medical help immediate- ly. 2.15  PORTABLE FIRE EXTINGUISHER. A pressurized fire extinguisher is mounted on a quick re- lease support located in the FAB fairing aft of the right FAB door and above the main landing gear wheel (fig 2-2). It is accessible through a hinged access panel and the panel is marked FIRE EXTINGUISHER INSIDE. The fire extin- guisher compound is released by a hand-operated lever on  top  of  the  extinguisher.  Inadvertent  discharge  of  the bottle is prevented by a breakaway safety wire across the actuating lever. Operating instructions are printed on the extinguisher. 2.16  ENGINE AND AUXILIARY POWER UNIT (APU) FIRE DETECTION. Two optical sensors, which react to visible flames, are lo- cated  in  each  engine  compartment  and  in  the  APU compartment.  Three  pneumatic  fire/overheat  detectors are located in the aft deck area. One detector is mounted on the main transmission support, and one on each of the two firewall louver doors. Amplified electrical signals from the sensors located in the engine compartment will illumi- nate the respective ENG FIRE PULL handle (fig 2-15) in both crew stations. The APU compartment sensors, or the aft deck fire/overheat detectors, will illuminate the  FIRE APU PULL handle (fig 2-15) in the pilot station and the FIRE APU segment on the MASTER CAUTION panel in both  crew  stations.  The  engine  fire  pull  handles  (ENG FIRE 1 PULL and ENG  FIRE 2 PULL) are located in simi- lar positions in both crew stations; they are at the upper left corner of the instrument panel. The FIRE APU PULL handle is located on the APU panel on the pilot right con- sole. 2.16.1  Engine and APU Fire Detector Testing. FIRE PULL handle lamps are tested by pressing the  PRESS TO TEST pushbutton on the MASTER CAUTION panel in either  crew  station.  The  fire  detector  circuits  receive  28 vdc from the emergency dc bus through the FIRE DETR circuit  breakers  (ENG 1,  ENG 2  and  APU)  on  the  pilot overhead circuit breaker panel (fig 2-39). The fire detector circuits are tested by turning the FIRE TEST DET rotary switch located on the pilots aft right console (fig 2-15). The switch  is  spring-loaded  to  OFF.  When  set  at  1,  the  first sensor circuit for No. 1 engine, No. 2 engine, APU, and left and right firewall louver door fire detectors are tested, which causes all FIRE PULL handles to illuminate. The FIRE APU segments on both MASTER CAUTION panels also illuminate. When the FIRE TEST DET switch is set at 2, the second sensor circuit for No. 1 engine, No. 2 en- gine,  APU,  and  main  transmission  support  fire  detector are  tested;  and  all  FIRE  PULL  handles  and  both  FIRE APU MASTER CAUTION panel segments will illuminate. In either test, failure of a handle to light up indicates a fault in that particular sensor circuit. 2.17  ENGINE AND APU FIRE EXTINGUISHING SYSTEM The  fire  extinguishing  agent  is  stored  in  two  spherical bottles,  each  containing  a  nitrogen  precharge.  The bottles, designated as primary (PRI) and reserve (RES) are mounted on the fuselage side of the No. 1 engine fire- wall.  Tubing  is  installed  to  distribute  the  extinguishing agent  to  either  of  the  engine  nacelles  or  to  the  APU compartment. Bottle integrity may be checked by inspect- ing the thermal relief discharge indicator which is viewed from below the left engine nacelle. A pressure gage on each bottle provides an indication of the nitrogen prechar- ge pressure. Each bottle has three discharge valves that can be individually actuated by an electrically ignited pyro- technic squib. There is one valve for each of the engine nacelles and one for the APU compartment. When a FIRE PULL handle is pulled, four events occur: fuel is shut off to the affected engine, engine cooling louvers to the affected engine close (not applicable to the APU), the appropriate squib firing circuit is armed, and the ENCU is shut off (not applicable to the APU). The extinguishing agent is not re- leased  to  the  fire  area,  however,  until  the  FIRE  BTL switch,  located  near  each  fire  pull  handle,  is  activated. The FIRE BTL switch is first set at PRI (primary bottle). When the fire is extinguished, the light in the

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing