Parts to be inepsctad
Up
TB-1-2840-229-20-17 Engine Vibration Screening and Recurring Inspection for all AH-1 Series Aircraft T53-L-703 Engine (P/N 1-000-060-23) Installed Manual
Next
Inspection Procedures cont'd

TB 1-2840-229-20-17
(3) Select option three (3).
(4) Select the number next to the T53N2 script file.
(5) After the file loads and the selection screen appears, press "QUIT" to return to the boot up
menu. Remove memory card and press "One" to proceed with normal AVA operation.
NOTE
If adapter mount (P/N LTCT535) is not available, units may fabricate the
adapter using the drawing supplied with the AVA Memory Card, The
adapter mount must meet the specifications of the drawing.
e. Modify adapter mount (P/N LTCT535) from Spectrum Analyzer Kit (NSN 6625-00-590-6502) as
follows:
(1) Drill hole 0.213 inch (#3) in top-center of adapter.
(2) Tap hole for threads 1/4 x 28 UNF.
(3) InstaIl accelerometer (NSN 6680-01-326-1913) from AVA Test Set into top of modified
adapter mount using two, flat washers (NSN 5310-00-141-1795) between bracket and accelerometer.
f.
AVA Test Set installation.
(1) Secure Data Acquisition Unit (DAU) in aircraft with canvas straps and "D" rings.
(2) Remove the assembly from one of the pilot's console lights. Remove the bulb. Plug
the AH-1 power cable adapter (29317100) lamp socket. Ensure that the lamp is set to full intensity
(clockwise).
(3) Connect the grounding clip to a screw head or any non-painted metal surface, which will
provide an adequate path to aircraft ground.
(4) Connect power cable to the DAU receptacle marked 28vDC.
(5) Locate Control and Display Unit (CADU) in aircraft and connect CADU to DAU cable
(29325601).
NOTE
Ensure adequate clearance between end of accelerometer threads and
mounting lug.
(6) Attach adapter and accelerometer assembly to upper-forward engine lifting eye, utilizing
hardware supplied in the Spectrum Analyzer Kit. There should be a bolt, washers, lock washer and nut in
that kit to secure the bracket to the lifting eye. Reference TM 55-2840-229-23-1, pages 1-214 and 1-215.
If the hardware is not available the following is a list of parts required:
NSN
DESCRIPTlON
PART NUMBER
AN8-23A
Bolt, Machine, Aircraft
5306-00-180-0097
1/2-20 UNF-3AX2, 15/32 LG
AN960-816
5310-01-259-1239
Washer, Flat
I AN935-816
5310-01-258-0051
Washer, Lock, Spring
AN315-8R
Nut, Plain, Airframe, 1/2-20
5310-00-298-9267
4