Figure 5. Bolt Tightening Pattern for the Lower Clamp Ring
Up
TB-1-1520-251-20-13 Replacement of Flange Ring on Electrical Power - Generator A.C. for AH-64D Helicopters Manual
Next
Table 1. Values of "A" for Drill Stop Depth Setting

TB 1-1520-251-20-13
CAUTION
If the ring position can not be shifted, peel the ring off the flange and
repeat the entire repair procedure with a new ring.
9.59
Allow the fixture to remain clamped in place for 90 minutes. The adhesive will set within this period.
CAUTION
The adhesive will not reach full performance characteristics until the
cure time has exceeded 24 hours.
9.60  After the 90 minutes set period has elapsed, insert a #42 drill bit, point first, into the depth gage block
until the drill bit stops.
9.61
Slide the drill stop on the drill bit until it is flush against the gage block.
9.62
Tighten the drill stop to the bit.
9.63  Remove the bit from the gage block and make sure of the drill stop position as shown in Figure 6 and
11