Up
TB-1-1520-251-20-13 Replacement of Flange Ring on Electrical Power - Generator A.C. for AH-64D Helicopters Manual
Next
PROCEDURES cont'd

TB 1-1520-251-20-13
Figure 4. No Marks Visible Through Index Windows (Acceptable Orientation)
CAUTION
If no position is possible with the index window guideline, do not pro-
ceed with this repair and return generator to Honeywell for evalua-
tion.
9.31  With the index, clamping, drill fixture in the desired position, mark the flange edge through the ring
split view hole and at the index notch on the flange face.
9.32
Remove the fixture from the generator flange.
9.33
Remove any adhesive labels put on during step 9.25 because they may affect the clamping of the ring.
CAUTION
Do not remove the label or the mark put on to identify the ring split
location.
9.34
Insert the proper plunger into the adhesive dispenser tool.
9.35
Assemble the adhesive cartridge into the dispenser.